Eaton EPM6242V-12R-042DR 1 W DC-DC Module, 24V Input
Eaton EPM6242V-12R-042DR 1 W DC-DC Module, 24V Input

Eaton EPM6242V-12R-042DR 1 W DC-DC Module, 24V Input

Share
EPM6242V-12R-042DR: Isolated DC-DC Converter, 24 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6242V-12R-042DR 1 W DC-DC Module, 24V Input

    EPM6242V-12R-042DR at a glance: Isolated DC-DC Converter, 24 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.

    Electrical Specifications

    ParameterValue
    Orderable part numberEPM6242V-12R-042DR
    Input voltage range24 Vdc
    Output voltage±12 Vdc
    Output current at full load±42 mA
    Output power0.5 W
    Efficiency, minimum77 %
    Efficiency, typical80 %
    Capacitive load, maximum220 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    How to Read These Ratings

    A one-watt isolated module with two output rails: ±3.3, ±5, ±12 or ±15 V from a 5, 12 or 24 V input. The two rails are regulated against each other only loosely, so the cross-regulation figure matters when the load is asymmetric.

    At 0.504 W out and 80 % typical efficiency the module dissipates about 0.13 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products