
| Parameter | Value |
|---|---|
| Orderable part number | EPM6242V-12R-084SR |
| Input voltage range | 24 Vdc |
| Output voltage | 12 Vdc |
| Output current at full load | 84 mA |
| Output power | 1.01 W |
| Efficiency, minimum | 76 % |
| Efficiency, typical | 79 % |
| Capacitive load, maximum | 470 uF |
| Isolation voltage | 3 kVdc |
| Package | SIP |
| Operating temperature | -40 °C to +100 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1163 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1163.
The module runs from a fixed input and produces ±V with no external parts. The isolation option in the part number selects standard or higher isolation voltage, which is the difference between the R and H suffixes.
At 1.008 W out and 79 % typical efficiency the module dissipates about 0.27 W. That is the number the thermal design has to carry, not the output power.
The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.
Is the total power 1 W per rail or in total?
In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.
Is the total power 1 W per rail or in total?
In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.
What is the difference between the R and H suffix?
The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd