Eaton EPM6242V-12R-084SR 1 W DC-DC Module, 24V Input
Eaton EPM6242V-12R-084SR 1 W DC-DC Module, 24V Input

Eaton EPM6242V-12R-084SR 1 W DC-DC Module, 24V Input

Share
EPM6242V-12R-084SR: Isolated DC-DC Converter, 24 V input, 12 V output, 84 mA, 1.01 W, 79 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6242V-12R-084SR 1 W DC-DC Module, 24V Input

    EPM6242V-12R-084SR at a glance: Isolated DC-DC Converter, 24 V input, 12 V output, 84 mA, 1.01 W, 79 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM6242V-12R-084SR
    Input voltage range24 Vdc
    Output voltage12 Vdc
    Output current at full load84 mA
    Output power1.01 W
    Efficiency, minimum76 %
    Efficiency, typical79 %
    Capacitive load, maximum470 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    The Figures Explained

    The module runs from a fixed input and produces ±V with no external parts. The isolation option in the part number selects standard or higher isolation voltage, which is the difference between the R and H suffixes.

    At 1.008 W out and 79 % typical efficiency the module dissipates about 0.27 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd