Eaton EPM6242V-15R-034DR Dual Output Isolated Converter
Eaton EPM6242V-15R-034DR Dual Output Isolated Converter

Eaton EPM6242V-15R-034DR Dual Output Isolated Converter

Share
EPM6242V-15R-034DR: Isolated DC-DC Converter, 24 V input, ±15 V output, ±34 mA, 0.51 W, 81 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6242V-15R-034DR Dual Output Isolated Converter

    EPM6242V-15R-034DR at a glance: Isolated DC-DC Converter, 24 V input, ±15 V output, ±34 mA, 0.51 W, 81 % typical efficiency.

    Electrical Specifications

    ParameterValue
    Orderable part numberEPM6242V-15R-034DR
    Input voltage range24 Vdc
    Output voltage±15 Vdc
    Output current at full load±34 mA
    Output power0.51 W
    Efficiency, minimum78 %
    Efficiency, typical81 %
    Capacitive load, maximum220 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    Reading the Data Sheet

    This is the dual-output version of the standard 1 W isolated module: same pin pitch, same isolation barrier, two rails out. The output current is quoted per rail, and the total still has to stay inside the watt rating.

    At 0.51 W out and 81 % typical efficiency the module dissipates about 0.12 W. That is the number the thermal design has to carry, not the output power.

    Where This Series Fits

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products