Eaton EPM7051V-12R-084SH 1 W DC-DC Module, 5V Input
Eaton EPM7051V-12R-084SH 1 W DC-DC Module, 5V Input

Eaton EPM7051V-12R-084SH 1 W DC-DC Module, 5V Input

Share
EPM7051V-12R-084SH: Isolated DC-DC Converter, 5 V input, 12 V output, 84 mA, 1.01 W, 78 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM7051V-12R-084SH 1 W DC-DC Module, 5V Input

    EPM7051V-12R-084SH at a glance: Isolated DC-DC Converter, 5 V input, 12 V output, 84 mA, 1.01 W, 78 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM7051V-12R-084SH
    Input voltage range5 Vdc
    Output voltage12 Vdc
    Output current at full load84 mA
    Output power1.01 W
    Efficiency, minimum75 %
    Efficiency, typical78 %
    Capacitive load, maximum470 uF
    Isolation voltage4 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1164

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1164.

    How to Read These Ratings

    A one-watt isolated DC-DC module in a SIP or DIP footprint: 5, 12 or 24 V in, single or dual output out, with galvanic isolation between the two sides. It is the part that breaks a ground loop or floats a gate driver supply when a full converter would be overkill.

    At 1.008 W out and 78 % typical efficiency the module dissipates about 0.28 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Can the output be paralleled?
    Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.

    Can the output be paralleled?
    Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.

    What does the isolation voltage mean in practice?
    It is the test voltage the barrier withstands, not a continuous working voltage. For reinforced insulation you also need the creepage on the board, which the module cannot provide on its own.