Eaton EPM7051V-3R3-152DH 1 W Isolated DC-DC Converter 5Vin
Eaton EPM7051V-3R3-152DH 1 W Isolated DC-DC Converter 5Vin

Eaton EPM7051V-3R3-152DH 1 W Isolated DC-DC Converter 5Vin

Share
EPM7051V-3R3-152DH: Isolated DC-DC Converter, 5 V input, ±3.3 V output, ±152 mA, 0.5 W, 75 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM7051V-3R3-152DH 1 W Isolated DC-DC Converter 5Vin

    EPM7051V-3R3-152DH at a glance: Isolated DC-DC Converter, 5 V input, ±3.3 V output, ±152 mA, 0.5 W, 75 % typical efficiency.

    Electrical Specifications

    ParameterValue
    Orderable part numberEPM7051V-3R3-152DH
    Input voltage range5 Vdc
    Output voltage±3.3 Vdc
    Output current at full load±152 mA
    Output power0.5 W
    Efficiency, minimum72 %
    Efficiency, typical75 %
    Capacitive load, maximum470 uF
    Isolation voltage4 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1164

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1164.

    How to Read These Ratings

    These modules are chosen for isolation first and power second. One watt at 70 to 85 percent efficiency is not a thermal problem; the questions are the isolation voltage, the regulation across the load range and whether the output can start into a capacitive load.

    At 0.5016 W out and 75 % typical efficiency the module dissipates about 0.17 W. That is the number the thermal design has to carry, not the output power.

    Where This Series Fits

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    What does the isolation voltage mean in practice?
    It is the test voltage the barrier withstands, not a continuous working voltage. For reinforced insulation you also need the creepage on the board, which the module cannot provide on its own.

    Can the output be paralleled?
    Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products