| Parameter | Value |
|---|---|
| Orderable part number | EPM7241V-12R-042DH |
| Input voltage range | 24 Vdc |
| Output voltage | ±12 Vdc |
| Output current at full load | ±42 mA |
| Output power | 0.5 W |
| Efficiency, minimum | 77 % |
| Efficiency, typical | 80 % |
| Capacitive load, maximum | 220 uF |
| Isolation voltage | 4 kVdc |
| Package | SIP |
| Operating temperature | -40 °C to +100 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1164 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1164.
Isolated modules like this appear wherever a signal has to cross a barrier: RS-485 transceivers, gate drivers, medical front ends, current shunt amplifiers. The 1 W rating is the continuous output; the input current at no load is a separate line in the data sheet.
At 0.504 W out and 80 % typical efficiency the module dissipates about 0.13 W. That is the number the thermal design has to carry, not the output power.
The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.
Why is the no-load input current specified?
Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.
Why is the no-load input current specified?
Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.
Does it need external capacitors?
The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.