| Parameter | Value |
|---|---|
| Orderable part number | EXLA1V0703-4R7-R |
| OCL | 4.7 uH ±20% |
| Irms | 9 A |
| Isat (30% rolloff @ +25 °C) | 12.2 A |
| DCR typical @ +25 °C | 24.2 mOhm |
| DCR maximum @ +25 °C | 26.7 mOhm |
| Rated operating voltage (across inductor) | 40 V |
| Package | 8.7 x 8.3 mm footprint, 3.1 mm height |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
Automotive qualification on a moulded inductor means the mechanical construction is as carefully specified as the electrical one: the moulded body survives thermal cycling, the shield keeps EMI out of the radios, and the soft-saturation core keeps the rail alive through transients at temperature.
DCR 24.2 mOhm is the conduction loss: at rated current it dissipates 1.96 W, and that heat has to leave through the terminals and the board.
Saturation on a powder core is a curve, not a cliff: Isat is the peak current for approximately 30% rolloff at +25 °C, and beyond it the inductance continues to fall smoothly. Budget the transient peak against the inductance you actually need, not against the part surviving.
The 155 °C rating is ambient plus self-heating, and the alloy powder core keeps its soft-saturation shape across that range - the transient behaviour at the hot corner is a milder version of the room-temperature curve, not a different part.
EXLA is the automotive moulded family: AEC-Q200 qualified, soft-saturating, shielded, rated to 155 °C - the power-inductor choice for ADAS, body electronics and infotainment rails.
Can I substitute it for the commercial EXL part of the same size?
The electrical rows are close, but the qualification, temperature range and the test data are not interchangeable. Substitute on the datasheet row, not on the family name.
What is the rated operating voltage?
A bias condition for characterisation (per size, 15 V or 40 V across the inductor). It is not an isolation rating.
Is this AEC-Q200 qualified?
Yes - the family is qualified to the automotive passive-component standard, including the terminal-strength and vibration test methods referenced on the datasheet.
Design note: budget the loss at the hot corner with the maximum DCR, and keep the transient peak below Isat with margin - the soft curve forgives, but does not eliminate, saturation.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.