| Parameter | Value |
|---|---|
| Orderable part number | EXLA1V0707-100-R |
| OCL | 10 uH ±20% |
| Irms | 7 A |
| Isat (30% rolloff @ +25 °C) | 9 A |
| DCR typical @ +25 °C | 24 mOhm |
| DCR maximum @ +25 °C | 26.4 mOhm |
| Rated operating voltage (across inductor) | 40 V |
| Package | 8.7 x 8.3 mm footprint, 7.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
Between the battery and the load sits a rail that must survive cranking transients, thermal cycling and vibration. This AEC-Q200 moulded inductor is built for that point in the circuit: high current, low DCR, and a saturation curve that degrades gracefully.
Copper loss is the efficiency floor. 24 mOhm at 25 °C rises about 30% by 100 °C, so the hot-corner budget should use the maximum column, not the typical.
Isat is the peak current for approximately 30% rolloff at +25 °C. In a multiphase converter the transient peak lands on the inductors before the loop corrects; a soft-saturating core keeps controlling di/dt through exactly that window.
The 155 °C rating is ambient plus self-heating, and the alloy powder core keeps its soft-saturation shape across that range - the transient behaviour at the hot corner is a milder version of the room-temperature curve, not a different part.
EXLA is the automotive moulded family: AEC-Q200 qualified, soft-saturating, shielded, rated to 155 °C - the power-inductor choice for ADAS, body electronics and infotainment rails.
What is the rated operating voltage?
A bias condition for characterisation (per size, 15 V or 40 V across the inductor). It is not an isolation rating.
What is the temperature range?
-55 °C to +155 °C, ambient plus self-temperature rise. The part should not exceed +155 °C under worst-case operating conditions.
What does "soft saturation" mean in practice?
The alloy powder core loses inductance gradually with current instead of collapsing. At transient peaks the inductor still limits di/dt - it is the behaviour that keeps a multiphase rail stable through load steps.
Design note: budget the loss at the hot corner with the maximum DCR, and keep the transient peak below Isat with margin - the soft curve forgives, but does not eliminate, saturation.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd