| Parameter | Value |
|---|---|
| Orderable part number | EXLA1V0707-5R6-R |
| OCL | 5.6 uH ±20% |
| Irms | 11.4 A |
| Isat (30% rolloff @ +25 °C) | 12 A |
| DCR typical @ +25 °C | 13.7 mOhm |
| DCR maximum @ +25 °C | 15 mOhm |
| Rated operating voltage (across inductor) | 40 V |
| Package | 8.7 x 8.3 mm footprint, 7.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
Automotive qualification on a moulded inductor means the mechanical construction is as carefully specified as the electrical one: the moulded body survives thermal cycling, the shield keeps EMI out of the radios, and the soft-saturation core keeps the rail alive through transients at temperature.
The typical and the maximum DCR are both quoted for a reason: production spread. A loss budget that has to hold across a build uses 13.7 mOhm as the optimistic case and plans against the maximum.
Isat is the peak current for approximately 30% rolloff at +25 °C. Because the rolloff is gradual, the useful design question is not "what happens at Isat" but "how much inductance do I still have at my transient peak" - and the soft curve answers that with a usable number.
The 155 °C rating is ambient plus self-heating, and the alloy powder core keeps its soft-saturation shape across that range - the transient behaviour at the hot corner is a milder version of the room-temperature curve, not a different part.
EXLA is the automotive moulded family: AEC-Q200 qualified, soft-saturating, shielded, rated to 155 °C - the power-inductor choice for ADAS, body electronics and infotainment rails.
Can I substitute it for the commercial EXL part of the same size?
The electrical rows are close, but the qualification, temperature range and the test data are not interchangeable. Substitute on the datasheet row, not on the family name.
What is the temperature range?
-55 °C to +155 °C, ambient plus self-temperature rise. The part should not exceed +155 °C under worst-case operating conditions.
Can I substitute it for the commercial EXL part of the same size?
The electrical rows are close, but the qualification, temperature range and the test data are not interchangeable. Substitute on the datasheet row, not on the family name.
Design note: budget the loss at the hot corner with the maximum DCR, and keep the transient peak below Isat with margin - the soft curve forgives, but does not eliminate, saturation.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.