FP0705R1-R15-R at a glance: 150 nH high frequency, high current power inductor, 43 A Irms, 30 A Isat, DCR 0.25 mOhm, 7.0 x 7.0 mm body, 4.95 mm tall.
FP0705R1-R15-R is one of Eaton's high frequency, high current power inductor series, 7.0 x 7.0 mm with a 4.95 mm tall profile. Electrically it offers 150 nH at 43 A Irms and 0.25 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP0705R1-R15-R |
| Inductance, OCL (0 Adc) | 150 nH |
| Inductance, FLL (minimum) | 108 nH |
| Irms (40 °C rise, no core loss) | 43 A |
| Isat (20% roll-off @ +25 °C) | 30 A |
| Isat2 (20% roll-off @ +125 °C) | 24 A |
| DCR typical @ +20 °C | 0.25 mOhm |
| K-factor (Bp-p = K x L x dI) | 826 |
| Package | 7.0 x 7.0 mm, 4.95 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 150 nH is measured with no DC in the winding, 108 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.
Peak current at 20% roll-off is 30 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 462 mW (43 A squared times 0.25 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Core loss needs flux, and flux here is about 111.5 mT for a 9 A ripple (K = 826). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 7.0 x 7.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 10 of 18 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.25 mOhm, Irms of 43 A is the top of the family.
The order of checks that works: compute ripple from 150 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.25 mOhm the winding is not the loss, the trace can be.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.