FP0705R2-R22-R at a glance: 226 nH high frequency, high current power inductor, 38 A Irms, 20 A Isat, DCR 0.32 mOhm, 7.0 x 7.0 mm body, 4.95 mm tall.
Eaton builds the FP0705R2-R22-R as a high frequency, high current power inductor for 7.0 x 7.0 mm footprints. At 226 nH and 38 A Irms with 0.32 mOhm of DCR it targets high-current DC-DC stages; the 4.95 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP0705R2-R22-R |
| Inductance, OCL (0 Adc) | 226 nH |
| Inductance, FLL (minimum) | 159 nH |
| Irms (40 °C rise, no core loss) | 38 A |
| Isat (20% roll-off @ +25 °C) | 20 A |
| Isat2 (20% roll-off @ +125 °C) | 16 A |
| DCR typical @ +20 °C | 0.32 mOhm |
| K-factor (Bp-p = K x L x dI) | 826 |
| Package | 7.0 x 7.0 mm, 4.95 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
226 nH open-circuit, 159 nH at full load: that is a 30% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Peak current at 20% roll-off is 20 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Irms of 38 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.32 mOhm that is roughly 462 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
The K-factor of 826 turns ripple into flux: a peak-to-peak swing of 6 A gives about 112 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 7.0 x 7.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 226 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 16 of 18 when the data sheet is sorted by inductance, DCR sits between the 0.25 and 0.46 mOhm the series covers.
The order of checks that works: compute ripple from 226 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.32 mOhm the winding is not the loss, the trace can be.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd