Eaton FP0708R1-R20-R 200 nH 36 A Saturation Inductor
Eaton FP0708R1-R20-R 200 nH 36 A Saturation Inductor

Eaton FP0708R1-R20-R 200 nH 36 A Saturation Inductor

Share
pEaton FP0708R1-R20-R: 200 nH high frequency, high current power inductor, 44 A Irms, 36 A Isat, DCR 0.35 mOhm, 7.0 x 8.5 mm package./p
    • Product Details
    • Download

    FP0708R1-R20-R at a glance: 200 nH high frequency, high current power inductor, 44 A Irms, 36 A Isat, DCR 0.35 mOhm, 7.0 x 8.5 mm body, 7.2 mm tall.

    Eaton FP0708R1-R20-R High frequency, high current power inductors

    FP0708R1-R20-R is one of Eaton's high frequency, high current power inductor series, 7.0 x 8.5 mm with a 7.2 mm tall profile. Electrically it offers 200 nH at 44 A Irms and 0.35 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.

    Electrical Specifications

    Orderable part numberFP0708R1-R20-R
    Inductance, OCL (0 Adc)200 nH
    Inductance, FLL (minimum)144 nH
    Irms (40 °C rise, no core loss)44 A
    Isat (20% roll-off @ +25 °C)36 A
    Isat2 (20% roll-off @ +125 °C)27 A
    DCR typical @ +20 °C0.35 mOhm
    K-factor (Bp-p = K x L x dI)557
    Package7.0 x 8.5 mm, 7.2 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    At zero bias the winding measures 200 nH. Put Isat1 through it and the figure falls to 144 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 200 nH number; loop stability and worst-case current belong on the lower one.

    Peak current at 20% roll-off is 36 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    Copper loss at the rated current works out at about 678 mW (44 A squared times 0.35 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.

    The K-factor of 557 turns ripple into flux: a peak-to-peak swing of 10.8 A gives about 120.3 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Where This Part Sits in the Range

    The 7.0 x 8.5 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 200 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it the highest inductance of the 7 parts in this data sheet.

    • Application fit: Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs), Server and desktop.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 200 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    On the board, place the part so the switch-node copper is short and wide. At 0.35 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Dimensions and Pad Layout

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP0708R1-R20-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products