pEaton FP0805R1-R06-R: 58 nH high frequency, high current power inductor, 65 A Irms, 83 A Isat, DCR 0.17 mOhm, 7.5 x 7.6 mm package./p
    • Product Details
    • Download

    FP0805R1-R06-R at a glance: 58 nH high frequency, high current power inductor, 65 A Irms, 83 A Isat, DCR 0.17 mOhm, 7.5 x 7.6 mm body, 5.0 mm tall.

    Eaton FP0805R1-R06-R High frequency, high current power inductors

    Eaton builds the FP0805R1-R06-R as a high frequency, high current power inductor for 7.5 x 7.6 mm footprints. At 58 nH and 65 A Irms with 0.17 mOhm of DCR it targets high-current DC-DC stages; the 5.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.

    Key Specifications

    Orderable part numberFP0805R1-R06-R
    Inductance, OCL (0 Adc)58 nH
    Inductance, FLL (minimum)42 nH
    Irms (40 °C rise, no core loss)65 A
    Isat (20% roll-off @ +25 °C)83 A
    Isat2 (20% roll-off @ +125 °C)61 A
    DCR typical @ +20 °C0.17 mOhm
    K-factor (Bp-p = K x L x dI)823.6
    Package7.5 x 7.6 mm, 5.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    58 nH open-circuit, 42 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.

    Saturation is quoted as 20% roll-off at 83 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.

    Irms of 65 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.17 mOhm that is roughly 718 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.

    Flux swing follows Bp-p = K x L x dI. With K = 823.6 and a ripple of 24.9 A the core sees roughly 118.9 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.

    Where This Part Sits in the Range

    The 7.5 x 7.6 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 58 nH this is a low-inductance point for the family, which means high ripple for a given input voltage and duty cycle. That is the intent: these parts are chosen when the converter switches fast and the inductor shapes the ripple rather than storing bulk energy.

    That makes it part 2 of 5 when the data sheet is sorted by inductance.

    • Application fit: Multi-phase and Vcore regulators.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Sizing It Into a Design

    Size the inductor on peak current first, not average. With 58 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.17 mOhm the winding is not the loss, the trace can be.

    Mechanical Dimensions and Pad Layout

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP0805R1-R06-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why is the saturation current listed at several temperatures?
    Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.