Eaton FP0807R1-R18-R 180 nH 42 A Saturation Inductor
Eaton FP0807R1-R18-R 180 nH 42 A Saturation Inductor

Eaton FP0807R1-R18-R 180 nH 42 A Saturation Inductor

Share
pEaton FP0807R1-R18-R: 180 nH high frequency, high current power inductor, 45 A Irms, 42 A Isat, DCR 32 mOhm, 8.0 x 7.0 mm package./p
    • Product Details
    • Download

    FP0807R1-R18-R at a glance: 180 nH high frequency, high current power inductor, 45 A Irms, 42 A Isat, DCR 32 mOhm, 8.0 x 7.0 mm body, 7.0 mm tall.

    Eaton FP0807R1-R18-R High frequency, high current power inductors

    Eaton FP0807R1-R18-R is a high frequency, high current power inductor in a 8.0 x 7.0 mm surface-mount package. It carries 180 nH of open-circuit inductance with 45 A Irms and a typical DCR of 32 mOhm, which places it in the switching stage of a multi-phase regulator rather than in bulk energy storage. The body is 7.0 mm tall and rated from -40 °C to +125 °C.

    Electrical Specifications

    Orderable part numberFP0807R1-R18-R
    Inductance, OCL (0 Adc)180 nH
    Inductance, FLL (minimum)129 nH
    Irms (40 °C rise, no core loss)45 A
    Isat (20% roll-off @ +25 °C)42 A
    DCR typical @ +20 °C32 mOhm
    K-factor (Bp-p = K x L x dI)520
    Package8.0 x 7.0 mm, 7.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    180 nH open-circuit, 129 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.

    The first Isat column, 42 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.

    The 64800 mW dissipated at 45 A through 32 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    The K-factor of 520 turns ripple into flux: a peak-to-peak swing of 12.6 A gives about 117.9 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Positioning in the FP Range

    The 8.0 x 7.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 180 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 5 of 7 when the data sheet is sorted by inductance, DCR sits between the 25 and 79 mOhm the series covers.

    • Application fit: Multi-phase and Vcore regulators, Voltage Regulator Module (VRM), Desktop and server VRMs and EVRDs.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Design Notes

    Size the inductor on peak current first, not average. With 180 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 32 mOhm the winding is not the loss, the trace can be.

    Mechanical Drawing

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP0807R1-R18-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Why is the saturation current listed at several temperatures?
    Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message