Eaton FP0807R1-R22-R - 220 nH Shielded Power Inductor 8.0 x 7.0 mm
Eaton FP0807R1-R22-R - 220 nH Shielded Power Inductor 8.0 x 7.0 mm

Eaton FP0807R1-R22-R - 220 nH Shielded Power Inductor 8.0 x 7.0 mm

Share
pEaton FP0807R1-R22-R: 220 nH high frequency, high current power inductor, 45 A Irms, 35 A Isat, DCR 25 mOhm, 8.0 x 7.0 mm package./p
    • Product Details
    • Download

    FP0807R1-R22-R at a glance: 220 nH high frequency, high current power inductor, 45 A Irms, 35 A Isat, DCR 25 mOhm, 8.0 x 7.0 mm body, 7.0 mm tall.

    Eaton FP0807R1-R22-R High frequency, high current power inductors

    The FP0807R1-R22-R is a 8.0 x 7.0 mm high frequency, high current power inductor from Eaton, rated 45 A Irms at 220 nH and 25 mOhm typical DCR. It is a surface-mount part 7.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Key Specifications

    Orderable part numberFP0807R1-R22-R
    Inductance, OCL (0 Adc)220 nH
    Inductance, FLL (minimum)158 nH
    Irms (40 °C rise, no core loss)45 A
    Isat (20% roll-off @ +25 °C)35 A
    DCR typical @ +20 °C25 mOhm
    K-factor (Bp-p = K x L x dI)520
    Package8.0 x 7.0 mm, 7.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    At zero bias the winding measures 220 nH. Put Isat1 through it and the figure falls to 158 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 220 nH number; loop stability and worst-case current belong on the lower one.

    Peak current at 20% roll-off is 35 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    Copper loss at the rated current works out at about 50625 mW (45 A squared times 25 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.

    Flux swing follows Bp-p = K x L x dI. With K = 520 and a ripple of 10.5 A the core sees roughly 120.1 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.

    Positioning in the FP Range

    The 8.0 x 7.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 220 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it the highest inductance of the 7 parts in this data sheet, and it shares the lowest DCR here at 25 mOhm.

    • Application fit: Multi-phase and Vcore regulators, Voltage Regulator Module (VRM), Desktop and server VRMs and EVRDs.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Sizing and Layout Notes

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 220 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 25 mOhm the winding is not the loss, the trace can be.

    Mechanical Dimensions and Pad Layout

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP0807R1-R22-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.