FP0905R1-R150-R at a glance: 150 nH high frequency, high current power inductor, 47 A Irms, 42 A Isat, DCR 610.8 mOhm, 9.0 x 7.0 mm body, 5.0 mm tall.
Eaton builds the FP0905R1-R150-R as a high frequency, high current power inductor for 9.0 x 7.0 mm footprints. At 150 nH and 47 A Irms with 610.8 mOhm of DCR it targets high-current DC-DC stages; the 5.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP0905R1-R150-R |
| Inductance, OCL (0 Adc) | 150 nH |
| Inductance, FLL (minimum) | 120 nH |
| Irms (40 °C rise, no core loss) | 47 A |
| Isat (20% roll-off @ +25 °C) | 42 A |
| DCR typical @ +20 °C | 610.8 mOhm |
| Package | 9.0 x 7.0 mm, 5.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 150 nH. Put Isat1 through it and the figure falls to 120 nH, about 20% lower, because the ferrite is partly saturated. Ripple calculations belong on the 150 nH number; loop stability and worst-case current belong on the lower one.
Peak current at 20% roll-off is 42 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Irms of 47 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 610.8 mOhm that is roughly 1349257 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 9.0 x 7.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
The order of checks that works: compute ripple from 150 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 610.8 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.
Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Shenzhen Gaorunxin Technology Co., Ltd