FP0906R1-R12-R at a glance: 120 nH high frequency, high current power inductor, 51 A Irms, 79 A Isat, DCR 0.29 mOhm, 9.6 x 6.45 mm body, 8.0 mm tall.
The FP0906R1-R12-R is a 9.6 x 6.45 mm high frequency, high current power inductor from Eaton, rated 51 A Irms at 120 nH and 0.29 mOhm typical DCR. It is a surface-mount part 8.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP0906R1-R12-R |
| Inductance, OCL (0 Adc) | 120 nH |
| Inductance, FLL (minimum) | 86 nH |
| Irms (40 °C rise, no core loss) | 51 A |
| Isat (20% roll-off @ +25 °C) | 79 A |
| Isat2 (20% roll-off @ +125 °C) | 68 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 451 |
| Package | 9.6 x 6.45 mm, 8.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 120 nH is measured with no DC in the winding, 86 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.
Saturation is quoted as 20% roll-off at 79 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Copper loss at the rated current works out at about 754 mW (51 A squared times 0.29 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Flux swing follows Bp-p = K x L x dI. With K = 451 and a ripple of 23.7 A the core sees roughly 128.3 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
The 9.6 x 6.45 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 2 of 7 when the data sheet is sorted by inductance.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 120 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
On the board, place the part so the switch-node copper is short and wide. At 0.29 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.