FP0906R1-R22-R at a glance: 220 nH high frequency, high current power inductor, 51 A Irms, 44 A Isat, DCR 0.29 mOhm, 9.6 x 6.45 mm body, 8.0 mm tall.
Eaton builds the FP0906R1-R22-R as a high frequency, high current power inductor for 9.6 x 6.45 mm footprints. At 220 nH and 51 A Irms with 0.29 mOhm of DCR it targets high-current DC-DC stages; the 8.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP0906R1-R22-R |
| Inductance, OCL (0 Adc) | 220 nH |
| Inductance, FLL (minimum) | 155 nH |
| Irms (40 °C rise, no core loss) | 51 A |
| Isat (20% roll-off @ +25 °C) | 44 A |
| Isat2 (20% roll-off @ +125 °C) | 37.5 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 451 |
| Package | 9.6 x 6.45 mm, 8.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 220 nH is measured with no DC in the winding, 155 nH with the winding loaded to Isat1. The gap between them is 30%, and it is the reason a converter that looks well damped at no load can ring at full current.
Saturation is quoted as 20% roll-off at 44 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 754 mW dissipated at 51 A through 0.29 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
Flux swing follows Bp-p = K x L x dI. With K = 451 and a ripple of 13.2 A the core sees roughly 131 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
The 9.6 x 6.45 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 220 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 5 of 7 when the data sheet is sorted by inductance.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 220 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
On the board, place the part so the switch-node copper is short and wide. At 0.29 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.