FP0910V2-R330-R at a glance: 330 nH high frequency, high current power inductor, 63 A Irms, 17 A Isat, DCR 0.125 mOhm, 9.0 x 10.0 mm body, 9.5 mm tall.
FP0910V2-R330-R is one of Eaton's high frequency, high current power inductor series, 9.0 x 10.0 mm with a 9.5 mm tall profile. Electrically it offers 330 nH at 63 A Irms and 0.125 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP0910V2-R330-R |
| Inductance, OCL (0 Adc) | 330 nH |
| Inductance, FLL (minimum) | 230 nH |
| Irms (40 °C rise, no core loss) | 63 A |
| Isat (20% roll-off @ +25 °C) | 17 A |
| Isat2 (20% roll-off @ +100 °C) | 14 A |
| Isat3 (20% roll-off @ +125 °C) | 13 A |
| DCR typical @ +20 °C | 0.125 mOhm |
| K-factor (Bp-p = K x L x dI) | 455 |
| Package | 9.0 x 10.0 mm, 9.5 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 330 nH is measured with no DC in the winding, 230 nH with the winding loaded to Isat1. The gap between them is 30%, and it is the reason a converter that looks well damped at no load can ring at full current.
Peak current at 20% roll-off is 17 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 496 mW (63 A squared times 0.125 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Core loss needs flux, and flux here is about 76.6 mT for a 5.1 A ripple (K = 455). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 9.0 x 10.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 330 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 5 of 7 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.125 mOhm, Irms of 63 A is the top of the family.
Size the inductor on peak current first, not average. With 330 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
On the board, place the part so the switch-node copper is short and wide. At 0.125 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.