FP1005R2-R08-R at a glance: 85 nH high frequency, high current power inductor, 50 A Irms, 90 A Isat, DCR 0.47 mOhm, 10.2 x 7.0 mm body, 4.95 mm tall.
The FP1005R2-R08-R is a 10.2 x 7.0 mm high frequency, high current power inductor from Eaton, rated 50 A Irms at 85 nH and 0.47 mOhm typical DCR. It is a surface-mount part 4.95 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP1005R2-R08-R |
| Inductance, OCL (0 Adc) | 85 nH |
| Inductance, FLL (minimum) | 61 nH |
| Irms (40 °C rise, no core loss) | 50 A |
| Isat (20% roll-off @ +25 °C) | 90 A |
| Isat2 (20% roll-off @ +125 °C) | 64 A |
| DCR typical @ +20 °C | 0.47 mOhm |
| K-factor (Bp-p = K x L x dI) | 536 |
| Package | 10.2 x 7.0 mm, 4.95 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
85 nH open-circuit, 61 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Peak current at 20% roll-off is 90 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 1175 mW (50 A squared times 0.47 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Core loss needs flux, and flux here is about 123 mT for a 27 A ripple (K = 536). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 10.2 x 7.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 85 nH this is a low-inductance point for the family, which means high ripple for a given input voltage and duty cycle. That is the intent: these parts are chosen when the converter switches fast and the inductor shapes the ripple rather than storing bulk energy.
That makes it the lowest inductance of the 16 parts in this data sheet, DCR sits between the 0.39 and 0.7 mOhm the series covers.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 85 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
On the board, place the part so the switch-node copper is short and wide. At 0.47 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd