FP1006R1-R10-R at a glance: 100 nH high frequency, high current power inductor, - A Irms, - A Isat, DCR 0.27 mOhm, 10.2 x 8.0 mm body, 6.0 mm tall.
The FP1006R1-R10-R is a 10.2 x 8.0 mm high frequency, high current power inductor from Eaton, rated - A Irms at 100 nH and 0.27 mOhm typical DCR. It is a surface-mount part 6.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP1006R1-R10-R |
| Inductance, OCL (0 Adc) | 100 nH |
| Inductance, FLL (minimum) | 72 nH |
| Isat2 (20% roll-off @ +125 °C) | 85 A |
| DCR typical @ +20 °C | 0.27 mOhm |
| K-factor (Bp-p = K x L x dI) | 454 |
| Package | 10.2 x 8.0 mm, 6.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
100 nH open-circuit, 72 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Saturation is quoted as 20% roll-off at - A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Copper loss at the rated current works out at about 0 mW (- A squared times 0.27 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 10.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 100 nH this is a low-inductance point for the family, which means high ripple for a given input voltage and duty cycle. That is the intent: these parts are chosen when the converter switches fast and the inductor shapes the ripple rather than storing bulk energy.
That makes it part 3 of 10 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.27 mOhm.
The order of checks that works: compute ripple from 100 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.27 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.