Eaton FP1006R1-R12-R 120 nH 53 A Saturation Inductor
Eaton FP1006R1-R12-R 120 nH 53 A Saturation Inductor

Eaton FP1006R1-R12-R 120 nH 53 A Saturation Inductor

Share
pEaton FP1006R1-R12-R: 120 nH high frequency, high current power inductor, A Irms, 53 A Isat, DCR 0.27 mOhm, 10.2 x 8.0 mm package./p
    • Product Details
    • Download

    FP1006R1-R12-R at a glance: 120 nH high frequency, high current power inductor, - A Irms, 53 A Isat, DCR 0.27 mOhm, 10.2 x 8.0 mm body, 6.0 mm tall.

    Eaton FP1006R1-R12-R High frequency, high current power inductors

    Eaton builds the FP1006R1-R12-R as a high frequency, high current power inductor for 10.2 x 8.0 mm footprints. At 120 nH and - A Irms with 0.27 mOhm of DCR it targets high-current DC-DC stages; the 6.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.

    Specification Table

    Orderable part numberFP1006R1-R12-R
    Inductance, OCL (0 Adc)120 nH
    Inductance, FLL (minimum)86 nH
    Isat (20% roll-off @ +25 °C)53 A
    Isat2 (20% roll-off @ +125 °C)71 A
    DCR typical @ +20 °C0.27 mOhm
    K-factor (Bp-p = K x L x dI)454
    Package10.2 x 8.0 mm, 6.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    120 nH open-circuit, 86 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.

    Saturation is quoted as 20% roll-off at 53 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.

    Copper loss at the rated current works out at about 0 mW (- A squared times 0.27 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.

    The K-factor of 454 turns ripple into flux: a peak-to-peak swing of 15.9 A gives about 86.6 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Positioning in the FP Range

    The 10.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 5 of 10 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.27 mOhm.

    • Application fit: Multi-phase and Vcore regulators.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    Size the inductor on peak current first, not average. With 120 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.

    On the board, place the part so the switch-node copper is short and wide. At 0.27 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Mechanical Dimensions and Pad Layout

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1006R1-R12-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why is the saturation current listed at several temperatures?
    Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.

    Shenzhen Gaorunxin Technology Co., Ltd