
FP1007R6-R27-R at a glance: 270 nH high frequency, high current power inductor, 61 A Irms, 41 A Isat, DCR 0.29 mOhm, 10.5 x 8.0 mm body, 7.0 mm max tall.
The FP1007R6-R27-R is a 10.5 x 8.0 mm high frequency, high current power inductor from Eaton, rated 61 A Irms at 270 nH and 0.29 mOhm typical DCR. It is a surface-mount part 7.0 mm max tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP1007R6-R27-R |
| Inductance, OCL (0 Adc) | 270 nH |
| Inductance, FLL (minimum) | 194 nH |
| Irms (40 °C rise, no core loss) | 61 A |
| Isat (20% roll-off @ +25 °C) | 41 A |
| Isat2 (20% roll-off @ +100 °C) | 33 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 348.8 |
| Package | 10.5 x 8.0 mm, 7.0 mm max height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
270 nH open-circuit, 194 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
The first Isat column, 41 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.
Irms of 61 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.29 mOhm that is roughly 1079 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
The K-factor of 348.8 turns ripple into flux: a peak-to-peak swing of 12.3 A gives about 115.8 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 10.5 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 270 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 4 of 7 when the data sheet is sorted by inductance.
The order of checks that works: compute ripple from 270 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
On the board, place the part so the switch-node copper is short and wide. At 0.29 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd