FP1008R5-R120-R at a glance: 120 nH high frequency, high current power inductor, 79 A Irms, 103 A Isat, DCR 0.17 mOhm, 10.8 x 8.0 mm body, 8.0 mm tall.
Eaton builds the FP1008R5-R120-R as a high frequency, high current power inductor for 10.8 x 8.0 mm footprints. At 120 nH and 79 A Irms with 0.17 mOhm of DCR it targets high-current DC-DC stages; the 8.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1008R5-R120-R |
| Inductance, OCL (0 Adc) | 120 nH |
| Inductance, FLL (minimum) | 86 nH |
| Irms (40 °C rise, no core loss) | 79 A |
| Isat (20% roll-off @ +25 °C) | 103 A |
| Isat2 (20% roll-off @ +100 °C) | 90 A |
| Isat3 (20% roll-off @ +125 °C) | 84 A |
| DCR typical @ +20 °C | 0.17 mOhm |
| K-factor (Bp-p = K x L x dI) | 342 |
| Package | 10.8 x 8.0 mm, 8.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 120 nH is measured with no DC in the winding, 86 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.
The first Isat column, 103 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.
The 1061 mW dissipated at 79 A through 0.17 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
The K-factor of 342 turns ripple into flux: a peak-to-peak swing of 30.9 A gives about 126.8 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 10.8 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 2 of 13 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.17 mOhm, Irms of 79 A is the top of the family.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 120 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.17 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd