FP1008R6-R300-R at a glance: 300 nH high frequency, high current power inductor, 74 A Irms, 36 A Isat, DCR 0.18 mOhm, 10.8 x 8.0 mm body, 8.0 mm tall.
FP1008R6-R300-R is one of Eaton's high frequency, high current power inductor series, 10.8 x 8.0 mm with a 8.0 mm tall profile. Electrically it offers 300 nH at 74 A Irms and 0.18 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP1008R6-R300-R |
| Inductance, OCL (0 Adc) | 300 nH |
| Inductance, FLL (minimum) | 216 nH |
| Irms (40 °C rise, no core loss) | 74 A |
| Isat (20% roll-off @ +25 °C) | 36 A |
| Isat2 (20% roll-off @ +100 °C) | 28 A |
| Isat3 (20% roll-off @ +125 °C) | 26 A |
| DCR typical @ +20 °C | 0.18 mOhm |
| K-factor (Bp-p = K x L x dI) | 342 |
| Package | 10.8 x 8.0 mm, 8.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
300 nH open-circuit, 216 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Saturation is quoted as 20% roll-off at 36 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Irms of 74 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.18 mOhm that is roughly 986 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
Core loss needs flux, and flux here is about 110.8 mT for a 10.8 A ripple (K = 342). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 10.8 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 300 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 12 of 13 when the data sheet is sorted by inductance, with the highest DCR in the series at 0.18 mOhm, which is what the extra turns cost, Irms of 74 A is the bottom of the family.
Size the inductor on peak current first, not average. With 300 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
On the board, place the part so the switch-node copper is short and wide. At 0.18 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.
Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.