FP1008R7-R150-R at a glance: 150 nH high frequency, high current power inductor, 72 A Irms, 72 A Isat, DCR 0.12 mOhm, 10.8 x 8.2 mm body, 8.2 mm tall.
FP1008R7-R150-R is one of Eaton's high frequency, high current power inductor series, 10.8 x 8.2 mm with a 8.2 mm tall profile. Electrically it offers 150 nH at 72 A Irms and 0.12 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP1008R7-R150-R |
| Inductance, OCL (0 Adc) | 150 nH |
| Inductance, FLL (minimum) | 108 nH |
| Irms (40 °C rise, no core loss) | 72 A |
| Isat (20% roll-off @ +25 °C) | 72 A |
| Isat2 (20% roll-off @ +100 °C) | 60 A |
| Isat3 (20% roll-off @ +125 °C) | 56 A |
| DCR typical @ +20 °C | 0.12 mOhm |
| K-factor (Bp-p = K x L x dI) | 361 |
| Package | 10.8 x 8.2 mm, 8.2 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 150 nH. Put Isat1 through it and the figure falls to 108 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 150 nH number; loop stability and worst-case current belong on the lower one.
Peak current at 20% roll-off is 72 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Irms of 72 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.12 mOhm that is roughly 622 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
Flux swing follows Bp-p = K x L x dI. With K = 361 and a ripple of 21.6 A the core sees roughly 117 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
The 10.8 x 8.2 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 3 of 4 when the data sheet is sorted by inductance.
Size the inductor on peak current first, not average. With 150 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
On the board, place the part so the switch-node copper is short and wide. At 0.12 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.