FP1012V2-R090-R at a glance: 90 nH high frequency, high current power inductor, 84 A Irms, - A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm body, 12.0 mm tall.
Eaton builds the FP1012V2-R090-R as a high frequency, high current power inductor for 10.0 x 6.0 mm footprints. At 90 nH and 84 A Irms with 0.125 mOhm of DCR it targets high-current DC-DC stages; the 12.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1012V2-R090-R |
| Inductance, OCL (0 Adc) | 90 nH |
| Inductance, FLL (minimum) | 64 nH |
| Irms (40 °C rise, no core loss) | 84 A |
| Isat2 (20% roll-off @ +100 °C) | 117 A |
| Isat3 (20% roll-off @ +125 °C) | 110 A |
| DCR typical @ +20 °C | 0.125 mOhm |
| K-factor (Bp-p = K x L x dI) | 305 |
| Package | 10.0 x 6.0 mm, 12.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
90 nH open-circuit, 64 nH at full load: that is a 29% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Saturation is quoted as 20% roll-off at - A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Copper loss at the rated current works out at about 882 mW (84 A squared times 0.125 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 10.0 x 6.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 90 nH this is a low-inductance point for the family, which means high ripple for a given input voltage and duty cycle. That is the intent: these parts are chosen when the converter switches fast and the inductor shapes the ripple rather than storing bulk energy.
That makes it part 5 of 16 when the data sheet is sorted by inductance.
Size the inductor on peak current first, not average. With 90 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.125 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.