
FP1012V2-R100-R at a glance: 100 nH high frequency, high current power inductor, 84 A Irms, 125 A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm body, 12.0 mm tall.
The FP1012V2-R100-R is a 10.0 x 6.0 mm high frequency, high current power inductor from Eaton, rated 84 A Irms at 100 nH and 0.125 mOhm typical DCR. It is a surface-mount part 12.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP1012V2-R100-R |
| Inductance, OCL (0 Adc) | 100 nH |
| Inductance, FLL (minimum) | 72 nH |
| Irms (40 °C rise, no core loss) | 84 A |
| Isat (20% roll-off @ +25 °C) | 125 A |
| Isat2 (20% roll-off @ +100 °C) | 105 A |
| Isat3 (20% roll-off @ +125 °C) | 100 A |
| DCR typical @ +20 °C | 0.125 mOhm |
| K-factor (Bp-p = K x L x dI) | 305 |
| Package | 10.0 x 6.0 mm, 12.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
100 nH open-circuit, 72 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Saturation is quoted as 20% roll-off at 125 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Copper loss at the rated current works out at about 882 mW (84 A squared times 0.125 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Flux swing follows Bp-p = K x L x dI. With K = 305 and a ripple of 37.5 A the core sees roughly 114.4 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
The 10.0 x 6.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 100 nH this is a low-inductance point for the family, which means high ripple for a given input voltage and duty cycle. That is the intent: these parts are chosen when the converter switches fast and the inductor shapes the ripple rather than storing bulk energy.
That makes it part 7 of 16 when the data sheet is sorted by inductance.
Size the inductor on peak current first, not average. With 100 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.125 mOhm the winding is not the loss, the trace can be.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd