FP1012V2-R120-R at a glance: 120 nH high frequency, high current power inductor, 84 A Irms, 105 A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm body, 12.0 mm tall.
FP1012V2-R120-R is one of Eaton's high frequency, high current power inductor series, 10.0 x 6.0 mm with a 12.0 mm tall profile. Electrically it offers 120 nH at 84 A Irms and 0.125 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP1012V2-R120-R |
| Inductance, OCL (0 Adc) | 120 nH |
| Inductance, FLL (minimum) | 86 nH |
| Irms (40 °C rise, no core loss) | 84 A |
| Isat (20% roll-off @ +25 °C) | 105 A |
| Isat2 (20% roll-off @ +100 °C) | 88 A |
| Isat3 (20% roll-off @ +125 °C) | 81 A |
| DCR typical @ +20 °C | 0.125 mOhm |
| K-factor (Bp-p = K x L x dI) | 305 |
| Package | 10.0 x 6.0 mm, 12.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 120 nH is measured with no DC in the winding, 86 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.
Saturation is quoted as 20% roll-off at 105 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Copper loss at the rated current works out at about 882 mW (84 A squared times 0.125 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Core loss needs flux, and flux here is about 115.3 mT for a 31.5 A ripple (K = 305). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 10.0 x 6.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 9 of 16 when the data sheet is sorted by inductance.
Size the inductor on peak current first, not average. With 120 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
On the board, place the part so the switch-node copper is short and wide. At 0.125 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.