FP1012V2-R470-R at a glance: 470 nH high frequency, high current power inductor, 84 A Irms, 22 A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm body, 12.0 mm tall.
Eaton builds the FP1012V2-R470-R as a high frequency, high current power inductor for 10.0 x 6.0 mm footprints. At 470 nH and 84 A Irms with 0.125 mOhm of DCR it targets high-current DC-DC stages; the 12.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1012V2-R470-R |
| Inductance, OCL (0 Adc) | 470 nH |
| Inductance, FLL (minimum) | 329 nH |
| Irms (40 °C rise, no core loss) | 84 A |
| Isat (20% roll-off @ +25 °C) | 22 A |
| Isat2 (20% roll-off @ +100 °C) | 19 A |
| Isat3 (20% roll-off @ +125 °C) | 18 A |
| DCR typical @ +20 °C | 0.125 mOhm |
| K-factor (Bp-p = K x L x dI) | 305 |
| Package | 10.0 x 6.0 mm, 12.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
470 nH open-circuit, 329 nH at full load: that is a 30% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Peak current at 20% roll-off is 22 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
The 882 mW dissipated at 84 A through 0.125 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
The K-factor of 305 turns ripple into flux: a peak-to-peak swing of 6.6 A gives about 94.6 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 10.0 x 6.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 470 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it the highest inductance of the 16 parts in this data sheet.
The order of checks that works: compute ripple from 470 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
On the board, place the part so the switch-node copper is short and wide. At 0.125 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.