Eaton FP1107R1-R12-R High Current Inductor, 120 nH 0.29 mOhm
Eaton FP1107R1-R12-R High Current Inductor, 120 nH 0.29 mOhm

Eaton FP1107R1-R12-R High Current Inductor, 120 nH 0.29 mOhm

Share
pEaton FP1107R1-R12-R: 120 nH high frequency, high current power inductor, 55 A Irms, 90 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm package./p
    • Product Details
    • Download

    FP1107R1-R12-R at a glance: 120 nH high frequency, high current power inductor, 55 A Irms, 90 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm body, 7.5 mm tall.

    Eaton FP1107R1-R12-R High frequency, high current power inductors

    The FP1107R1-R12-R is a 11.2 x 8.0 mm high frequency, high current power inductor from Eaton, rated 55 A Irms at 120 nH and 0.29 mOhm typical DCR. It is a surface-mount part 7.5 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Specification Table

    Orderable part numberFP1107R1-R12-R
    Inductance, OCL (0 Adc)120 nH
    Inductance, FLL (minimum)86 nH
    Irms (40 °C rise, no core loss)55 A
    Isat (20% roll-off @ +25 °C)90 A
    Isat4 (20% roll-off @ +125 °C)72 A
    DCR typical @ +20 °C0.29 mOhm
    K-factor (Bp-p = K x L x dI)361.1
    Package11.2 x 8.0 mm, 7.5 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    Moisture sensitivity levelMSL 1
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    Two inductance figures are published. 120 nH is measured with no DC in the winding, 86 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.

    Saturation is quoted as 20% roll-off at 90 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.

    Irms of 55 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.29 mOhm that is roughly 877 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.

    The K-factor of 361.1 turns ripple into flux: a peak-to-peak swing of 27 A gives about 117 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Positioning in the FP Range

    The 11.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 4 of 22 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.29 mOhm, Irms of 55 A is the top of the family.

    • Application fit: Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs), Server and desktop.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Sizing and Layout Notes

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 120 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    On the board, place the part so the switch-node copper is short and wide. At 0.29 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Dimensions and Pad Layout

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP1107R1-R12-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    How is the part packed?
    Tape and reel, with the reel quantity stated in the packaging section of the data sheet. The parts are polarised by the terminal marking, so check orientation in the reel before setting up the feeder.

    Why is the saturation current listed at several temperatures?
    Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.