Eaton FP1107R5-R120-R High Current Inductor, 120 nH 0.29 mOhm
Eaton FP1107R5-R120-R High Current Inductor, 120 nH 0.29 mOhm

Eaton FP1107R5-R120-R High Current Inductor, 120 nH 0.29 mOhm

Share
pEaton FP1107R5-R120-R: 120 nH high frequency, high current power inductor, 55 A Irms, 90 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm package./p
    • Product Details
    • Download

    FP1107R5-R120-R at a glance: 120 nH high frequency, high current power inductor, 55 A Irms, 90 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm body, 7.5 mm tall.

    Eaton FP1107R5-R120-R High frequency, high current power inductors

    FP1107R5-R120-R is one of Eaton's high frequency, high current power inductor series, 11.2 x 8.0 mm with a 7.5 mm tall profile. Electrically it offers 120 nH at 55 A Irms and 0.29 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.

    Ratings at a Glance

    Orderable part numberFP1107R5-R120-R
    Inductance, OCL (0 Adc)120 nH
    Inductance, FLL (minimum)86 nH
    Irms (40 °C rise, no core loss)55 A
    Isat (20% roll-off @ +25 °C)90 A
    Isat4 (20% roll-off @ +125 °C)72 A
    DCR typical @ +20 °C0.29 mOhm
    K-factor (Bp-p = K x L x dI)361.1
    Package11.2 x 8.0 mm, 7.5 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    Moisture sensitivity levelMSL 1
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    120 nH open-circuit, 86 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.

    Peak current at 20% roll-off is 90 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    The 877 mW dissipated at 55 A through 0.29 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    The K-factor of 361.1 turns ripple into flux: a peak-to-peak swing of 27 A gives about 117 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Positioning in the FP Range

    The 11.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 4 of 22 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.29 mOhm, Irms of 55 A is the top of the family.

    • Application fit: Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs), Server and desktop.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Sizing It Into a Design

    The order of checks that works: compute ripple from 120 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.

    On the board, place the part so the switch-node copper is short and wide. At 0.29 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Mechanical Dimensions and Pad Layout

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1107R5-R120-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    What does the R suffix on the part number mean?
    It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.