FP1107R5-R150-R at a glance: 150 nH high frequency, high current power inductor, 55 A Irms, 70 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm body, 7.5 mm tall.
Eaton builds the FP1107R5-R150-R as a high frequency, high current power inductor for 11.2 x 8.0 mm footprints. At 150 nH and 55 A Irms with 0.29 mOhm of DCR it targets high-current DC-DC stages; the 7.5 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1107R5-R150-R |
| Inductance, OCL (0 Adc) | 150 nH |
| Inductance, FLL (minimum) | 108 nH |
| Irms (40 °C rise, no core loss) | 55 A |
| Isat (20% roll-off @ +25 °C) | 70 A |
| Isat4 (20% roll-off @ +125 °C) | 56 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 361.1 |
| Package | 11.2 x 8.0 mm, 7.5 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 150 nH. Put Isat1 through it and the figure falls to 108 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 150 nH number; loop stability and worst-case current belong on the lower one.
Saturation is quoted as 20% roll-off at 70 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 877 mW dissipated at 55 A through 0.29 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
The K-factor of 361.1 turns ripple into flux: a peak-to-peak swing of 21 A gives about 113.7 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 11.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 7 of 22 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.29 mOhm, Irms of 55 A is the top of the family.
The order of checks that works: compute ripple from 150 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.