FP1109B1-R180-R at a glance: 180 nH high frequency, high current power inductor, 55 A Irms, 62 A Isat, DCR 0.19 mOhm, 11.0 x 8.2 mm body, 9.0 mm tall.
Eaton builds the FP1109B1-R180-R as a high frequency, high current power inductor for 11.0 x 8.2 mm footprints. At 180 nH and 55 A Irms with 0.19 mOhm of DCR it targets high-current DC-DC stages; the 9.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1109B1-R180-R |
| Inductance, OCL (0 Adc) | 180 nH |
| Inductance, FLL (minimum) | 130 nH |
| Irms (40 °C rise, no core loss) | 55 A |
| Isat (20% roll-off @ +25 °C) | 62 A |
| Isat2 (20% roll-off @ +125 °C) | 49 A |
| DCR typical @ +20 °C | 0.19 mOhm |
| K-factor (Bp-p = K x L x dI) | 339 |
| Package | 11.0 x 8.2 mm, 9.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 180 nH. Put Isat1 through it and the figure falls to 130 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 180 nH number; loop stability and worst-case current belong on the lower one.
The first Isat column, 62 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.
Irms of 55 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.19 mOhm that is roughly 575 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
Core loss needs flux, and flux here is about 113.5 mT for a 18.6 A ripple (K = 339). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 11.0 x 8.2 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 180 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 2 of 4 when the data sheet is sorted by inductance.
Size the inductor on peak current first, not average. With 180 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.19 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.