FP1110V1-R22-R at a glance: 220 nH high frequency, high current power inductor, 61 A Irms, 64 A Isat, DCR 0.23 mOhm, 11.0 x 10.0 mm body, 9.5 mm tall.
The FP1110V1-R22-R is a 11.0 x 10.0 mm high frequency, high current power inductor from Eaton, rated 61 A Irms at 220 nH and 0.23 mOhm typical DCR. It is a surface-mount part 9.5 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP1110V1-R22-R |
| Inductance, OCL (0 Adc) | 220 nH |
| Inductance, FLL (minimum) | 158 nH |
| Irms (40 °C rise, no core loss) | 61 A |
| Isat (20% roll-off @ +100 °C) | 64 A |
| Isat2 (20% roll-off @ +100 °C) | 51 A |
| DCR typical @ +20 °C | 0.23 mOhm |
| K-factor (Bp-p = K x L x dI) | 278 |
| Package | 11.0 x 10.0 mm, 9.5 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
220 nH open-circuit, 158 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Saturation is quoted as 20% roll-off at 64 A at +100 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 856 mW dissipated at 61 A through 0.23 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
Flux swing follows Bp-p = K x L x dI. With K = 278 and a ripple of 19.2 A the core sees roughly 117.4 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
The 11.0 x 10.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 220 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 6 of 11 when the data sheet is sorted by inductance, with the highest DCR in the series at 0.23 mOhm, which is what the extra turns cost.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 220 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
On the board, place the part so the switch-node copper is short and wide. At 0.23 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

How is the part packed?
Tape and reel, with the reel quantity stated in the packaging section of the data sheet. The parts are polarised by the terminal marking, so check orientation in the reel before setting up the feeder.
Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.
Shenzhen Gaorunxin Technology Co., Ltd