Eaton FP1206R1-R15-R 150 nH 70 A Saturation Inductor
Eaton FP1206R1-R15-R 150 nH 70 A Saturation Inductor

Eaton FP1206R1-R15-R 150 nH 70 A Saturation Inductor

Share
pEaton FP1206R1-R15-R: 150 nH high frequency, high current power inductor, 50 A Irms, 70 A Isat, DCR 0.43 mOhm, 8.0 x 12.0 mm package./p
    • Product Details
    • Download

    FP1206R1-R15-R at a glance: 150 nH high frequency, high current power inductor, 50 A Irms, 70 A Isat, DCR 0.43 mOhm, 8.0 x 12.0 mm body, 6.0 mm tall.

    Eaton FP1206R1-R15-R High frequency, high current power inductors

    Eaton builds the FP1206R1-R15-R as a high frequency, high current power inductor for 8.0 x 12.0 mm footprints. At 150 nH and 50 A Irms with 0.43 mOhm of DCR it targets high-current DC-DC stages; the 6.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.

    Specification Table

    Orderable part numberFP1206R1-R15-R
    Inductance, OCL (0 Adc)150 nH
    Inductance, FLL (minimum)108 nH
    Irms (40 °C rise, no core loss)50 A
    Isat (20% roll-off @ +25 °C)70 A
    Isat2 (20% roll-off @ +125 °C)51 A
    DCR typical @ +20 °C0.43 mOhm
    K-factor (Bp-p = K x L x dI)358
    Package8.0 x 12.0 mm, 6.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Two inductance figures are published. 150 nH is measured with no DC in the winding, 108 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.

    Peak current at 20% roll-off is 70 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    The 1075 mW dissipated at 50 A through 0.43 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    Flux swing follows Bp-p = K x L x dI. With K = 358 and a ripple of 21 A the core sees roughly 112.8 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.

    Where This Part Sits in the Range

    At 8.0 x 12.0 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 2 of 5 when the data sheet is sorted by inductance.

    • Application fit: Multi-phase and Vcore regulators.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 150 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.43 mOhm the winding is not the loss, the trace can be.

    Dimensions and Pad Layout

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1206R1-R15-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Is this part AEC-Q200 qualified?
    No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.