Eaton FP1208R1-R15-R 50 A SMD Power Inductor, 150 nH
Eaton FP1208R1-R15-R 50 A SMD Power Inductor, 150 nH

Eaton FP1208R1-R15-R 50 A SMD Power Inductor, 150 nH

Share
pEaton FP1208R1-R15-R: 150 nH high frequency, high current power inductor, 50 A Irms, 85 A Isat, DCR 0.29 mOhm, 12.0 x 8.0 mm package./p
    • Product Details
    • Download

    FP1208R1-R15-R at a glance: 150 nH high frequency, high current power inductor, 50 A Irms, 85 A Isat, DCR 0.29 mOhm, 12.0 x 8.0 mm body, 8.0 mm tall.

    Eaton FP1208R1-R15-R High frequency, high current power inductors

    The FP1208R1-R15-R is a 12.0 x 8.0 mm high frequency, high current power inductor from Eaton, rated 50 A Irms at 150 nH and 0.29 mOhm typical DCR. It is a surface-mount part 8.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Ratings at a Glance

    Orderable part numberFP1208R1-R15-R
    Inductance, OCL (0 Adc)150 nH
    Inductance, FLL (minimum)114 nH
    Irms (40 °C rise, no core loss)50 A
    Isat (20% roll-off @ +25 °C)85 A
    Isat2 (20% roll-off @ +85 °C)79 A
    Isat3 (20% roll-off @ +125 °C)72 A
    DCR typical @ +20 °C0.29 mOhm
    K-factor (Bp-p = K x L x dI)283
    Package12.0 x 8.0 mm, 8.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    At zero bias the winding measures 150 nH. Put Isat1 through it and the figure falls to 114 nH, about 24% lower, because the ferrite is partly saturated. Ripple calculations belong on the 150 nH number; loop stability and worst-case current belong on the lower one.

    Saturation is quoted as 20% roll-off at 85 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.

    Irms of 50 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.29 mOhm that is roughly 725 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.

    Flux swing follows Bp-p = K x L x dI. With K = 283 and a ripple of 25.5 A the core sees roughly 108.2 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.

    Series Positioning

    At 12.0 x 8.0 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it the lowest inductance of the 5 parts in this data sheet.

    • Application fit: Multi-phase and Vcore regulators.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Design Notes

    The order of checks that works: compute ripple from 150 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.

    Outline Drawing

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1208R1-R15-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    What does the R suffix on the part number mean?
    It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products