FP1308-R32-R at a glance: 320 nH high frequency, high current power inductor, 68 A Irms, 45 A Isat, DCR 0.2 mOhm, 13.7 x 12.9 mm body, 8.0 mm tall.
FP1308-R32-R is one of Eaton's high frequency, high current power inductor series, 13.7 x 12.9 mm with a 8.0 mm tall profile. Electrically it offers 320 nH at 68 A Irms and 0.2 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP1308-R32-R |
| Inductance, OCL (0 Adc) | 320 nH |
| Irms (40 °C rise, no core loss) | 68 A |
| Isat (20% roll-off @ +25 °C) | 45 A |
| DCR typical @ +20 °C | 0.2 mOhm |
| DCR maximum @ +20 °C | 0.24 mOhm |
| K-factor (Bp-p = K x L x dI) | 21.3 |
| Package | 13.7 x 12.9 mm, 8.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
320 nH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
The first Isat column, 45 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.
Copper loss at the rated current works out at about 925 mW (68 A squared times 0.2 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Flux swing follows Bp-p = K x L x dI. With K = 21.3 and a ripple of 13.5 A the core sees roughly 9.2 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
At 13.7 x 12.9 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 320 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 4 of 5 when the data sheet is sorted by inductance.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 320 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.2 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.