Eaton FP1505R1-R15-R 53 A SMD Power Inductor, 150 nH
Eaton FP1505R1-R15-R 53 A SMD Power Inductor, 150 nH

Eaton FP1505R1-R15-R 53 A SMD Power Inductor, 150 nH

Share
pEaton FP1505R1-R15-R: 150 nH high frequency, high current power inductor, 53 A Irms, 72 A Isat, DCR 0.47 mOhm, 7.0 x 15.0 mm package./p
    • Product Details
    • Download

    FP1505R1-R15-R at a glance: 150 nH high frequency, high current power inductor, 53 A Irms, 72 A Isat, DCR 0.47 mOhm, 7.0 x 15.0 mm body, 5.0 mm tall.

    Eaton FP1505R1-R15-R High frequency, high current power inductors

    FP1505R1-R15-R is one of Eaton's high frequency, high current power inductor series, 7.0 x 15.0 mm with a 5.0 mm tall profile. Electrically it offers 150 nH at 53 A Irms and 0.47 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.

    Ratings at a Glance

    Orderable part numberFP1505R1-R15-R
    Inductance, OCL (0 Adc)150 nH
    Inductance, FLL (minimum)108 nH
    Irms (40 °C rise, no core loss)53 A
    Isat (20% roll-off @ +25 °C)72 A
    Isat2 (20% roll-off @ +125 °C)60 A
    DCR typical @ +20 °C0.47 mOhm
    K-factor (Bp-p = K x L x dI)356.3
    Package7.0 x 15.0 mm, 5.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    The Figures Explained

    150 nH open-circuit, 108 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.

    The first Isat column, 72 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.

    The 1320 mW dissipated at 53 A through 0.47 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    The K-factor of 356.3 turns ripple into flux: a peak-to-peak swing of 21.6 A gives about 115.4 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Positioning in the FP Range

    At 7.0 x 15.0 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 3 of 6 when the data sheet is sorted by inductance.

    • Application fit: Multi-phase and Vcore regulators.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 150 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.47 mOhm the winding is not the loss, the trace can be.

    Outline Drawing

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1505R1-R15-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.