FP1507R1-R185-R at a glance: 185 nH high current power inductor, 45 A Irms, 40 A Isat, DCR 0.52 mOhm, 15.1 x 8.5 mm body, 6.7 mm tall.
Eaton FP1507R1-R185-R is a high current power inductor in a 15.1 x 8.5 mm surface-mount package. It carries 185 nH of open-circuit inductance with 45 A Irms and a typical DCR of 0.52 mOhm, which places it in the switching stage of a multi-phase regulator rather than in bulk energy storage. The body is 6.7 mm tall and rated from -55 °C to +125 °C.
| Orderable part number | FP1507R1-R185-R |
| Inductance, OCL (0 Adc) | 185 nH |
| Inductance, FLL (minimum) | 163 nH |
| Irms (40 °C rise, no core loss) | 45 A |
| Isat (2% roll-off @ +25 °C) | 40 A |
| DCR typical @ +20 °C | 0.52 mOhm |
| Package | 15.1 x 8.5 mm, 6.7 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -55 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
185 nH open-circuit, 163 nH at full load: that is a 12% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
The first Isat column, 40 A at +25 °C, is the peak the part takes at 2% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.
Copper loss at the rated current works out at about 1053 mW (45 A squared times 0.52 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
At 15.1 x 8.5 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 185 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 185 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.52 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

How is the part packed?
Tape and reel, with the reel quantity stated in the packaging section of the data sheet. The parts are polarised by the terminal marking, so check orientation in the reel before setting up the feeder.
What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.