FP3-8R2-R at a glance: 8.5 uH high current, low profile inductor, 2.91 A Irms, 2.6 A Isat, DCR 61.6 mOhm, 7.25 x 6.7 mm body, 3.0 mm tall.
Eaton builds the FP3-8R2-R as a high current, low profile inductor for 7.25 x 6.7 mm footprints. At 8.5 uH and 2.91 A Irms with 61.6 mOhm of DCR it targets high-current DC-DC stages; the 3.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +155 °C.
| Orderable part number | FP3-8R2-R |
| Inductance, OCL (0 Adc) | 8.5 uH |
| Irms (40 °C rise, no core loss) | 2.91 A |
| Isat | 2.6 A |
| Isat2 | 3.4 A |
| DCR typical @ +20 °C | 61.6 mOhm |
| DCR maximum @ +20 °C | 74 mOhm |
| K-factor (Bp-p = K x L x dI) | 78 |
| Package | 7.25 x 6.7 mm, 3.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +155 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
8.5 uH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
Peak current at the quoted roll-off is 2.6 A. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Irms of 2.91 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 61.6 mOhm that is roughly 522 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
Core loss needs flux, and flux here is about 51.7 mT for a 0.78 A ripple (K = 78). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
This is one of the smaller bodies in the FP range. At 7.25 x 6.7 mm it is meant for point-of-load stages and multi-phase VRMs where board area is the binding constraint and current per phase is tens of amps rather than hundreds. At 8.5 uH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 10 of 12 when the data sheet is sorted by inductance, DCR sits between the 1 and 106 mOhm the series covers.
The order of checks that works: compute ripple from 8.5 uH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
On the board, place the part so the switch-node copper is short and wide. At 61.6 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.