FP3-R20-R at a glance: 220 nH high current, low profile inductor, 15.3 A Irms, 16 A Isat, DCR 1.54 mOhm, 7.25 x 6.7 mm body, 3.0 mm tall.
Eaton builds the FP3-R20-R as a high current, low profile inductor for 7.25 x 6.7 mm footprints. At 220 nH and 15.3 A Irms with 1.54 mOhm of DCR it targets high-current DC-DC stages; the 3.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +155 °C.
| Orderable part number | FP3-R20-R |
| Inductance, OCL (0 Adc) | 220 nH |
| Irms (40 °C rise, no core loss) | 15.3 A |
| Isat | 16 A |
| Isat2 | 20.8 A |
| DCR typical @ +20 °C | 1.54 mOhm |
| DCR maximum @ +20 °C | 1.88 mOhm |
| K-factor (Bp-p = K x L x dI) | 482 |
| Package | 7.25 x 6.7 mm, 3.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +155 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
220 nH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
Peak current at the quoted roll-off is 16 A. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 360 mW (15.3 A squared times 1.54 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
The K-factor of 482 turns ripple into flux: a peak-to-peak swing of 4.8 A gives about 50.9 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
This is one of the smaller bodies in the FP range. At 7.25 x 6.7 mm it is meant for point-of-load stages and multi-phase VRMs where board area is the binding constraint and current per phase is tens of amps rather than hundreds. At 220 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 2 of 12 when the data sheet is sorted by inductance, DCR sits between the 1 and 106 mOhm the series covers.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 220 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 1.54 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.
Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Shenzhen Gaorunxin Technology Co., Ltd