FP4-120-R at a glance: 120 nH high current power inductor, 40 A Irms, 54 A Isat, DCR 0.38 mOhm, 10.2 x 6.8 mm body, 5.0 mm tall.
Eaton builds the FP4-120-R as a high current power inductor for 10.2 x 6.8 mm footprints. At 120 nH and 40 A Irms with 0.38 mOhm of DCR it targets high-current DC-DC stages; the 5.0 mm tall body keeps the height budget in check, and the part is rated from -45 °C to +155 °C.
| Orderable part number | FP4-120-R |
| Inductance, OCL (0 Adc) | 120 nH |
| Irms (40 °C rise, no core loss) | 40 A |
| Isat (20% roll-off @ +25 °C) | 54 A |
| DCR typical @ +20 °C | 0.38 mOhm |
| DCR maximum @ +20 °C | 0.65 mOhm |
| Volt-microsecond rating | 1.33 V-us |
| Package | 10.2 x 6.8 mm, 5.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -45 °C to +155 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
120 nH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
Saturation is quoted as 20% roll-off at 54 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 608 mW dissipated at 40 A through 0.38 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 10.2 x 6.8 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 3 of 5 when the data sheet is sorted by inductance, Irms of 40 A is the top of the family.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 120 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.38 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.