FPT1006-400-R at a glance: 400 nH dual conductor high current power inductor, 19 A Irms, 35.5 A Isat, DCR 1 mOhm, 10.5 x 8.8 mm body, 6.4 mm tall.
Eaton FPT1006-400-R is a dual conductor high current power inductor in a 10.5 x 8.8 mm surface-mount package. It carries 400 nH of open-circuit inductance with 19 A Irms and a typical DCR of 1 mOhm, which places it in the switching stage of a multi-phase regulator rather than in bulk energy storage. The body is 6.4 mm tall and rated from -40 °C to +125 °C.
| Orderable part number | FPT1006-400-R |
| Inductance, OCL (0 Adc) | 400 nH |
| Irms (40 °C rise, no core loss) | 19 A |
| Isat (5% roll-off @ +25 °C) | 35.5 A |
| DCR typical @ +20 °C | 1 mOhm |
| Package | 10.5 x 8.8 mm, 6.4 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
400 nH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
Peak current at 5% roll-off is 35.5 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Irms of 19 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 1 mOhm that is roughly 361 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 10.5 x 8.8 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 400 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 2 of 4 when the data sheet is sorted by inductance.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 400 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 1 mOhm the winding is not the loss, the trace can be.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd