FPT705-230-R at a glance: 230 nH dual conductor, high current power inductor, 13 A Irms, 23 A Isat, DCR 0.65 mOhm, 8.3 x 7.5 mm body, 5.35 mm tall.
FPT705-230-R is one of Eaton's dual conductor, high current power inductor series, 8.3 x 7.5 mm with a 5.35 mm tall profile. Electrically it offers 230 nH at 13 A Irms and 0.65 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FPT705-230-R |
| Inductance, OCL (0 Adc) | 230 nH |
| Irms (40 °C rise, no core loss) | 13 A |
| Isat | 23 A |
| DCR typical @ +20 °C | 0.65 mOhm |
| Package | 8.3 x 7.5 mm, 5.35 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -55 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
230 nH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
The first Isat column, 23 A, is the peak the part takes at the quoted roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.
Copper loss at the rated current works out at about 110 mW (13 A squared times 0.65 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 8.3 x 7.5 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 230 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 4 of 6 when the data sheet is sorted by inductance.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 230 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
On the board, place the part so the switch-node copper is short and wide. At 0.65 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.