Eaton GBA-1-1/2 1.5 A 125 Vac Pin-Indicating Fast-Acting Fuse
Eaton GBA-1-1/2 1.5 A 125 Vac Pin-Indicating Fast-Acting Fuse

Eaton GBA-1-1/2 1.5 A 125 Vac Pin-Indicating Fast-Acting Fuse

Share
Eaton GBA-1-1/2 is a 1.5 A pin-indicating fast-acting fuse in a 6.3 x 32 mm body, 125 Vac with a 10,000 A interrupting rating.
    • Product Details
    • Download

    Eaton GBA-1-1/2 1.5 A 125 Vac Pin-Indicating Fast-Acting Fuse

    The GBA-1-1/2 is the 1.5 A part of the GBA family - a 6.3 x 32 mm body with a red indicating pin rated 125 Vac with 10,000 A interrupting capacity.

    Core Specifications

    ParameterValue
    Manufacturer / SeriesEaton / GBA Series
    Orderable part numberGBA-1-1/2 (carton of 100)
    Current rating1.5 A (1/2 A)
    Voltage rating125 Vac
    Interrupting rating10,000 A
    Approval basisUL Listed + CSA Certified
    Indicating pinred
    Body1/4 x 1-1/4 in (6.3 x 32 mm) body with red indicating pin
    Fuse typenon-time-delay (fast acting), pin indicating
    AgencyUL Listed guide JDYX file E19180 (1/2-5 A); UL Recognized guide JDYX2 file E19180 (6 A, 10-15 A); CSA Certified class 1422-01 file 53787 (1/2-5 A); CE
    Environmentalno RoHS or halogen-free claim is made on this datasheet

    At 1.5 A

    • Interruption. 10,000 A at the rated voltage is what this part is tested to clear. Above that the enclosure rather than the element decides what happens, so the prospective fault current is part of the application check, not only the load.
    • Position in the range. Sits between GBA-1 and GBA-2 in the range. Stepping down to GBA-1 trips sooner on light overload but leaves less continuous headroom; GBA-2 trades the other way.

    Where 1.5 A Fits

    1.5 A is normally specified for desktop and appliance power inlets - single-phase equipment inlets and adapter outputs. If the measured steady current already sits within 20 % of 1.5 A, the next rating up in the same body is the safer release.

    Rating-Specific Notes

    • This rating is 125 Vac / 10,000 A and UL Listed (guide JDYX) plus CSA certified.

    For Procurement

    • Order GBA-1-1/2. The orderable reference on this page reads GBA-1-1/2 (carton of 100); the packaging prefix, where the series uses one, goes in front of the part number rather than after it.
    • Agency / compliance for this rating: UL Listed guide JDYX file E19180 (1/2-5 A); UL Recognized guide JDYX2 file E19180 (6 A, 10-15 A); CSA Certified class 1422-01 file 53787 (1/2-5 A); CE.
    • 1.5 A is not interchangeable with the neighbouring rating beyond its name: the current, the terminal arrangement and the body dimensions all have to match.

    Frequently Asked Questions

    Will GBA-1-1/2 carry 1.5 A continuously without opening?
    Yes. The published table shows no opening at 100 % of rating, so 1.5 A is inside the continuous rating at 25 C. Ambient temperature inside the enclosure, not the nominal current, is what usually forces the next size up.

    What fault current can GBA-1-1/2 clear?
    10,000 A at rated voltage. That figure assumes a normal branch-circuit source impedance; a stiff transformer feeding the same circuit can exceed it, and then the fuse is no longer the protective device by design.

    Can GBA-1-1/2 replace the next rating up in an existing design?
    No. Dropping from a higher rating changes both the continuous headroom and the I2t, so a fuse that used to ride through inrush may now open on it. Match current, voltage, I2t and body before substituting.

    Design note: resistance, I2t and voltage-drop values are typical unless identified as ratings. Verify the current data sheet and curves before release.