Eaton GMD-1-R 1 A Slow-Blow Cartridge Fuse, Glass, 5 x 20 mm
Eaton GMD-1-R 1 A Slow-Blow Cartridge Fuse, Glass, 5 x 20 mm

Eaton GMD-1-R 1 A Slow-Blow Cartridge Fuse, Glass, 5 x 20 mm

Share
pEaton GMD-1-R — 1 A, 250 V, time-delay glass cartridge fuse, 5 x 20 mm, 35 A at 250 Vac; 10,000 A at 125 Vac interrupting./p
    • Product Details
    • Download

    Eaton GMD-1-R 1 A Slow-Blow Cartridge Fuse, Glass, 5 x 20 mm

    Built by Eaton, the GMD-1-R carries 1 A, rated 250 Vac, uses a slow-blow element, in a glass body, measuring 5 x 20 mm.

    Technical Data

    ParameterRating
    Part numberGMD-1-R
    BodyGlass tube, 5 x 20 mm
    End capsnickel-plated brass
    Typical DC cold resistance0.1995 Ω
    Design standardUL/CSA 248-14
    Voltage rating250 Vac
    Elementsingle element
    AC interrupting rating35 A at 250 Vac; 10,000 A at 125 Vac
    Rated current1 A
    Typical melting I2t12 A²s
    Maximum voltage drop310 mV

    Selection Notes

    • Interrupting capability is 35 A at 250 Vac; 10,000 A at 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Footprint 5 x 20 mm — check clip or holder compatibility before substitution.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 1 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV

    Q&A

    What are the ratings of the GMD-1-R?

    1 A continuous at 250 Vac, interrupting rating 35 A at 250 Vac; 10,000 A at 125 Vac.

    Is the GMD-1-R fast-acting or time-delay?

    It is slow-blow. It tolerates short inrush surges.

    What size is the GMD-1-R?

    It measures 5 x 20 mm. Match the holder or clip to this footprint.

    Can the GMD-1-R be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.