| Parameter | Value |
|---|---|
| Orderable part number | HC1-3R6-R |
| OCL (open circuit inductance) | 3.59 uH ±15% |
| Irms (DC, 40 °C rise) | 16.8 A |
| Isat (30% rolloff @ +20 °C) | 13.4 A |
| DCR typical @ +20 °C | 3.5 mOhm |
| Volt-time rating (V-us) | 9.16 |
| Package | 13.0 x 10.0 mm |
| Height | 4.9 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4328 |

Drawing reproduced from Eaton Technical Data 4328: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Where a power rail delivers tens of amps at a volt or two, the inductor is effectively a short circuit that happens to store energy. The foil construction here minimises the resistance of that short circuit while the ferrite core holds the inductance, which is why the family is used on distributed power and server-class converters.
Copper loss at the rated current works out to roughly 0.983 W from a typical DCR of 3.5 mOhm at 16.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 30% rolloff @ +20 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 322 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.
Within the HC1 family this is value 8 of 11, in a range that runs from 0.218 uH to 10.5 uH.
One step down the table, HC1-2R3-R, sits at 2.29 uH with 22.3 A and 2 mOhm – the lower inductance buys about 9.51 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 3.5 mOhm becomes roughly 4.94 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.
What does the DCR tolerance mean for paralleling?
Parts are not matched for DCR, so two in parallel will not share current exactly. The mismatch is set by the DCR tolerance, and because the DCR is only fractions of a milliohm, a small absolute difference is a large percentage one.
What does the volt-microsecond column describe?
It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.
What does the volt-microsecond column describe?
It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.
Shenzhen Gaorunxin Technology Co., Ltd