| Parameter | Value |
|---|---|
| Orderable part number | HC1-R87-R |
| OCL (open circuit inductance) | 0.866 uH ±15% |
| Irms (DC, 40 °C rise) | 28 A |
| Isat (30% rolloff @ +20 °C) | 31 A |
| DCR typical @ +20 °C | 1.23 mOhm |
| Volt-time rating (V-us) | 5.49 |
| Package | 13.0 x 10.0 mm |
| Height | 4.9 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4328 |

Drawing reproduced from Eaton Technical Data 4328: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This part belongs to the HC foil family, built for high-current, low-voltage converters where efficiency is dominated by the copper. Ferrite keeps core loss low at the switching frequency; the foil winding keeps the copper loss low at the DC component. Both halves of the loss budget are addressed in the same body.
At the rated 28 A the winding dissipates about 0.965 W in copper alone, using the typical DCR of 1.23 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 30% rolloff @ +20 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 416 uJ, the number that connects the inductance and the current rating into a single transient figure.
The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.
In the HC1 line-up this part is number 4 of 11 by inductance, between 0.218 uH and 10.5 uH.
Compared with its neighbours in the table, HC1-1R0-R trades 9.82 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.23 mOhm becomes roughly 1.74 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.
Is the part suitable for a SEPIC or buck-boost stage?
The inductance and current ratings suit it, but check the AC flux swing: in a buck-boost the inductor carries the full input current continuously, so the core loss is higher than in a buck stage of the same output.
Why foil instead of round wire?
At high frequency the current crowds into the surface of the conductor. A flat foil presents a wide surface for the same cross-section, so the AC resistance stays closer to the DC value and the winding runs cooler.
Is the part suitable for a SEPIC or buck-boost stage?
The inductance and current ratings suit it, but check the AC flux swing: in a buck-boost the inductor carries the full input current continuously, so the core loss is higher than in a buck stage of the same output.