| Parameter | Value |
|---|---|
| Orderable part number | HC3-4R7-R |
| OCL (open circuit inductance) | 4.98 uH ±20% |
| Irms (DC, 40 °C rise) | 33.8 A |
| Isat (20% rolloff @ +25 °C) | 38 A |
| DCR typical @ +20 °C | 2.17 mOhm |
| Volt-time rating (V-us) | 43.3 |
| Package | 30.0 x 25.3 mm |
| Height | 18.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4122 |

Drawing reproduced from Eaton Technical Data 4122: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This part belongs to the HC foil family, built for high-current, low-voltage converters where efficiency is dominated by the copper. Ferrite keeps core loss low at the switching frequency; the foil winding keeps the copper loss low at the DC component. Both halves of the loss budget are addressed in the same body.
Copper loss at the rated current works out to roughly 2.48 W from a typical DCR of 2.17 mOhm at 33.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Stored energy at Isat is about 3,596 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.
Within the HC3 family this is value 5 of 7, in a range that runs from 0.5 uH to 6.52 uH.
Compared with its neighbours in the table, HC3-5R6-R trades 8.65 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.17 mOhm becomes roughly 3.07 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.
Why foil instead of round wire?
At high frequency the current crowds into the surface of the conductor. A flat foil presents a wide surface for the same cross-section, so the AC resistance stays closer to the DC value and the winding runs cooler.
Why foil instead of round wire?
At high frequency the current crowds into the surface of the conductor. A flat foil presents a wide surface for the same cross-section, so the AC resistance stays closer to the DC value and the winding runs cooler.
Why foil instead of round wire?